Viessmann Heat Pump: Purge the domestic hot water (DHW) lines
Purge the domestic hot water (DHW) lines on a Viessmann heat pump: Air left in the unit and the lines between the DHW tank and the unit will cavitate and damage the pump. Purging the building plumbing alone does not clear the unit.
Applies to: Domestic hot water circuit
How to fix purge the domestic hot water (dhw) lines: step by step
- Close boiler drain valves and the isolation valves.
- Open the cold supply to the DHW tank.
- Open a hot tap and bleed air from the tank, or lift the tank relief valve lever.
- Purge the air remaining in the unit and the lines to the hot water tank.
- Confirm all air is removed from the DHW lines before running the unit for hot water.
If the unit shows an error code, look it up: Viessmann Heat Pump codes
Models
AP1T 027020AP1T 040029AP1T 052038AP1T 066049AP1T 077056
More commissioning tips for heat pump
Source: Vitocal 100-WA installation, service and operating instructions, p. 44. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.