Viessmann Heat Pump: Preparing the work area before refrigerant circuit work
Preparing the work area before refrigerant circuit work on a Viessmann heat pump: Reduce fire and leak risk before opening the refrigerant circuit.
Applies to: R32 refrigerant circuit work
How to fix preparing the work area before refrigerant circuit work: step by step
- Tell all maintenance staff and people nearby about the work.
- Close off the area around the heat pump.
- Check the surroundings for combustible materials and ignition sources, and remove them.
- Post no-smoking signs.
- Work outdoors or ventilate the area well before cooling-circuit, welding or soldering work.
- Keep ventilation running at all times.
- Have a CO2 or powder fire extinguisher available when charging refrigerant or doing welding or soldering.
If the unit shows an error code, look it up: Viessmann Heat Pump codes
Models
0200280340430510780340043AM2V 020028AM2V 034043AM2V 051078
Source: Vitocal 100-AW AM2V Installation, Service and Operating Instructions, p. 89. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.