Viessmann Heat Pump: Handling and tilting the outdoor module
Handling and tilting the outdoor module on a Viessmann heat pump: Sharp tilting can let compressor oil enter the refrigerant circuit and cause a start-up failure.
Applies to: Outdoor unit AM2V 020028, 034043, 051078
Common causes of handling and tilting the outdoor module
- Sharp tilt lets compressor oil migrate into the refrigeration circuit.
How to fix handling and tilting the outdoor module: step by step
- Do not tilt the outdoor module beyond 30 degrees.
- If a tilt beyond 30 degrees is needed, do not exceed 45 degrees and hold it there for no more than about 4 minutes.
- Do not press on the outdoor unit jacketing; strong impacts can damage it.
- Route wall ducts and protective conduits for piping and wiring without bends and without changing direction.
- Run electrical cables without tension.
If the unit shows an error code, look it up: Viessmann Heat Pump codes
Models
0200280340430510780340043AM2V 020028AM2V 034043AM2V 051078
Source: Vitocal 100-AW AM2V Technical Data Manual, p. 25. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.