Viessmann Heat Pump: Electrical and component checks before energising a flammable refrigerant system
Electrical and component checks before energising a flammable refrigerant system on a Viessmann heat pump: Make safety checks before power is restored to any circuit with a fault that could affect safety.
Applies to: Vitocal 100-AW AM2V
How to fix electrical and component checks before energising a flammable refrigerant system: step by step
- Discharge capacitors in a way that cannot spark.
- Make sure no live components or wiring are exposed while charging, recovering or purging.
- Confirm earth bonding continuity.
- Replace sealed electrical components instead of repairing them. Replace intrinsically safe components too.
- Check cabling for wear, corrosion, excess pressure, vibration, sharp edges and aging.
- Check that refrigerant pipes are not exposed to corrosive substances unless they are protected.
- Confirm the refrigerant charge matches the room size and that ventilation is clear and working.
- Keep equipment markings legible and correct any that are not.
If the unit shows an error code, look it up: Viessmann Heat Pump codes
Models
0200280340430510780340043AM2V 020028AM2V 034043AM2V 051078
Source: Vitocal 100-AW AM2V installation, service and operating instructions, p. 9. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.