How to fix connect desuperheater to dhw tank: step by step
- Turn off power or fuel to the DHW tank and close the cold water supply valve.
- Drain the tank through the drain connection, opening a nearby faucet or relief valve to speed draining.
- Remove the drain fitting after draining.
- Install isolation ball valves and two drain valves so the pump can be serviced without draining the tank.
- Install a horizontal swing check valve to prevent tank overheating.
- Use metal fittings within 12 in (300 mm) of the desuperheater tee.
- Use mechanical fittings at a plastic (Marathon) tank; do not solder or braze near it.
- Match copper pipe size to the unit fittings; if 1 in (25 mm) copper is used, reduce it as close to the tank as possible.
- Never use plastic fittings between the tank and the unit.
- Follow the tank manufacturer's installation instructions.
If the unit shows an error code, look it up: Viessmann Heat Pump codes
Models
AP1T 027020AP1T 040029AP1T 052038AP1T 066049AP1T 077056
Source: Vitocal 100-WA Installation, Service and Operating Instructions, p. 30. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.