Viessmann Heat Pump: Antifreeze and water treatment at fill
Antifreeze and water treatment at fill on a Viessmann heat pump: Treat the fill water where minerals or hardness are known to be a problem, and add antifreeze only where freezing can occur.
Applies to: Vitocal 100-AW hydronic system
How to fix antifreeze and water treatment at fill: step by step
- Check hardness and pH of the fill and top-up water before filling.
- If hardness is high or pH is out of range after operation, take corrective treatment.
- Keep antifreeze at or below 50% glycol and check the system often when it is filled with antifreeze.
- Check that a backflow preventer is in the automatic water feed when a glycol mix is used.
- Tell the system operator the system contains glycol and provide the antifreeze Safety Data Sheet (SDS).
If the unit shows an error code, look it up: Viessmann Heat Pump codes
Models
0200280340430510780340043AM2V 020028AM2V 034043AM2V 051078
More commissioning tips for heat pump
Source: Vitocal 100-AW AM2V Installation, Service and Operating Instructions, p. 110. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.