Viessmann Boiler: Wiring the 0-10 V input extension module

Updated · by Aurora Star Tech Inc.

Wiring the 0-10 V input extension module on a Viessmann boiler: Module powered from 120 V / 60 Hz, with a 0 to 10 V input, KM-BUS link to the control unit, a zero-volt contact and a T 250 mA fuse.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: 0-10 V input extension module

How to fix wiring the 0-10 v input extension module: step by step

  1. Connect the 120 V / 60 Hz supply, with a mains disconnect if required.
  2. Connect the 0 to 10 V signal to the VF input.
  3. Connect the KM-BUS link from the module to the control unit.
  4. Connect the zero-volt contact.
  5. Set the DIP switches as shown in the DIP switch table.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Boiler codes

Models

HO1BKW2Vitotronic 200, type H01BVitotronic 200, Type HO1B

Source: Vitotronic 200 KW2 service instructions, p. 82. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.