Updated · by Aurora Star Tech Inc.

Underfloor heating restrictions on a Viessmann boiler: Underfloor heating responds slowly, so room sensing and direct remote control are restricted on that circuit.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Underfloor heating circuits

How to fix underfloor heating restrictions: step by step

  1. Do not let the RS function influence an underfloor heating circuit.
  2. Do not control the underfloor circuit with a remote control that has a room temperature sensor.
  3. Install an accessory kit for operation of the underfloor circuit with a mixing valve.
  4. Install a temperature control with high limit in the flow of the radiant floor application.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Boiler codes

More commissioning tips for boiler

Source: Vitotronic 300 technical data manual, p. 2, p. 5. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.