Updated · by Aurora Star Tech Inc.

System version 4: return temperature control with low loss header and three-way mixing valve on a Viessmann boiler: Vitorond 200 boiler with Vitotronic 100 GC1 on each boiler and one Vitotronic 300-K MW1S. The return temperature is controlled with a three-way mixing valve and a low loss header. Sensor T1 closes the mixing valve in proportion when the minimum return temperature is not reached, which protects the boiler. The sensor in the low loss header controls the supply temperature. Suited to older systems, systems where the hydraulics are not clearly defined, and systems where downstream heating circuits cannot be controlled.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: System version 4, Vorond 200 with Vitotronic 100 GC1 and Vitotronic 300-K MW1S

How to fix system version 4: return temperature control with low loss header and three-way mixing valve: step by step

  1. Code every Vitotronic 100 GC1 as shown in the system version 4 coding table.
  2. Size each boiler circuit pump so its flow is at least the maximum total heating circuit flow; recommended 110%.
  3. Check the connection diagram on site for completeness and function, because it is only a recommendation.
  4. Wire single-phase and three-phase pumps through field-supplied motor contactors or starters.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Boiler codes

Models

Vitotronic 100, type GC1

Source: Vitotronic 100 GC1 / 300-K MW1S installation and service instructions, p. 16-17. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.