Viessmann Boiler: System version 2: underfloor heating with heat exchanger
System version 2: underfloor heating with heat exchanger on a Viessmann boiler: Underfloor heating is separated from the boiler circuit by a heat exchanger. A high limit aquastat limits the maximum temperature downstream of the mixing valve and heating circuit pump. The heating circuit pump is wired through the aquastat. Optional return sensor is used with the supply sensor on socket X6.
Applies to: Underfloor heating circuit with heat exchanger
How to fix system version 2: underfloor heating with heat exchanger: step by step
- Install a high limit aquastat downstream of the mixing valve and heating circuit pump.
- Connect the heating circuit pump to the aquastat as shown in the diagram.
- Connect the outdoor sensor to X3 and the supply/return sensor to X6.
- Connect external controls to X5 (aVD).
If the unit shows an error code, look it up: Viessmann Boiler codes
Models
HK1BHK1MHK1SHK3SVitotrol 200Vitotrol 300
Source: Vitotronic 200-H installation and service instructions, p. 7. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.