Viessmann Boiler: Stopping DHW heating
Stopping DHW heating on a Viessmann boiler: Two options depending on whether the rooms still need heat.
Applies to: DHW heating and heating circuits
Common causes of stopping dhw heating
- Customer does not want DHW or room heating
- Customer wants room heat but not DHW
How to fix stopping dhw heating: step by step
- To stop both DHW and room heating: for the header circuit, select Standby mode in the standard menu and confirm with OK; for other circuits, go to extended menu > Heating > Heating program > Standby mode.
- To keep room heating but stop DHW: go to extended menu > Heating > Heating program > Heating and DHW.
- Go to DHW setpoint temperature and set it to 50°F (10°C).
If the unit shows an error code, look it up: Viessmann Boiler codes
Source: Vitotrol 300A operating instructions, p. 16. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.