Viessmann Boiler: Set the same DHW heating cycles for every day of the week
Set the same DHW heating cycles for every day of the week on a Viessmann boiler: DHW has four cycles. Default is cycle 1 from 05:30 to 22:00 every day. The automatic mode is preselected, so DHW heats 30 minutes before the space heating program starts.
Applies to: Vitotrol 300 remote control, DHW time program
How to fix set the same dhw heating cycles for every day of the week: step by step
- Open the flip-down cover of the remote control.
- Select 'Time Prog. DHW' and wait for the screen to appear.
- Select 'Individual?' and confirm to keep it off for the same-every-day setting.
- Select 'DHW Heating Cycle 1' and then 'DHW Heating Cycle 1 On'.
- Set the start time and confirm; the display changes to 'DHW Heating Cycle 1 Off'.
- Set the end time and confirm; the display changes to 'DHW Heating Cycle 1 On'.
- Set cycles 2 to 4 the same way.
- Close the cover.
- To skip a cycle, press the skip key. To leave early, press the exit key.
If the unit shows an error code, look it up: Viessmann Boiler codes
Source: Vitotrol 300 operating instructions, p. 14. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.