Viessmann Boiler: Sensor and external connection sockets
Sensor and external connection sockets on a Viessmann boiler: The control has a sockets for the outdoor sensor, supply sensor and external controls. The return sensor is an accessory on the supply sensor socket for underfloor systems.
Applies to: Vitotronic 200-H control unit
How to fix sensor and external connection sockets: step by step
- Connect the outdoor temperature sensor (ATS) to socket X3.
- Connect the supply temperature sensor to socket X6. For underfloor systems with the optional return sensor, use X6 for the supply/return sensor.
- Connect external controls to socket X5 (aVD). See page 13 for details.
If the unit shows an error code, look it up: Viessmann Boiler codes
Models
HK1BHK1MHK1SHK3SVitotrol 200Vitotrol 300
Source: Vitotronic 200-H installation and service instructions, p. 6 and p. 7. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.