Viessmann Boiler: Installing the KM-BUS Expansion Module
Installing the KM-BUS Expansion Module on a Viessmann boiler: Mount the module near the boiler, connect the accessories, and link the module to the Vitotronic control unit.
Applies to: Up to 9 KM-BUS devices (mixing valve actuator kits, Vitotrol, Switching Module-V) on a Vitotronic control, which is the only control series this module is for.
How to fix installing the km-bus expansion module: step by step
- Open the KM-BUS Expansion Module.
- Mount the base on the wall with the screws and wall anchors supplied. Install it near the boiler because of the length of the KM-BUS connecting cable.
- Connect accessories to terminals "1" and "2" on the plug, or to terminal strip "X8" on the module.
- Connect the plug to the module circuit board in sockets X1 to X7.
- Insert the plug of the module's connecting cable into socket "145" on the control unit and apply strain relief.
- Check all connections against the Electrical Connections diagram before closing the module.
If the unit shows an error code, look it up: Viessmann Boiler codes
Source: KM-BUS Expansion Module installation instructions, p. 1-2. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.