Viessmann Boiler: Heating pump off after high limit aquastat trip
Heating pump off after high limit aquastat trip on a Viessmann boiler: The aquastat switches the heating circuit pump off when the set limit is exceeded. Because the supply temperature falls only slowly, the system may take several hours to restart automatically.
Applies to: Heating circuit with high limit aquastat
Common causes of heating pump off after high limit aquastat trip
- Supply temperature above the aquastat set value
How to fix heating pump off after high limit aquastat trip: step by step
- Check the supply temperature and the aquastat set value.
- Allow time for the supply temperature to fall; automatic restart can take several hours.
- Check the system for the cause of overheating before resetting or changing the setting.
If the unit shows an error code, look it up: Viessmann Boiler codes
Models
HK1BHK1MHK1SHK3SVitotrol 200Vitotrol 300
Source: Vitotronic 200-H installation and service instructions, p. 6. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.