Viessmann Boiler: Connecting the burner or vent system cable
Connecting the burner or vent system cable on a Viessmann boiler: The Vitotronic 200 is prewired with plug-in connectors. If a venting system is installed, the 7-pole plug goes to the wall vent system and not directly to the burner.
Applies to: Vitotronic 200 KW2 with burner or wall vent system
How to fix connecting the burner or vent system cable: step by step
- Connect the Rast-5 plug-in connector to the main circuit board of the control.
- Connect the 7-pole plug to the counter plug of the burner.
- If a venting system is installed, connect the 7-pole plug to the counter plug of the wall vent system instead.
- Refer to the burner or wall vent system instructions for details.
If the unit shows an error code, look it up: Viessmann Boiler codes
Models
HO1BKW2Vitotronic 200, type H01BVitotronic 200, Type HO1B
Source: Vitotronic 200 KW2 service instructions, p. 83. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.