Viessmann Boiler: Connect several remote controls
Connect several remote controls on a Viessmann boiler: Use an on-site terminal box when more than one remote control is connected. The total KM BUS cable length should be limited, and each remote branch should be kept short.
Applies to: Vitotrol remotes on KM BUS
How to fix connect several remote controls: step by step
- Install a terminal box on site.
- Connect the control unit to the terminal box.
- Connect each remote control (Vitotrol 1, 2, 3) to the terminal box as shown in the diagram.
- Keep each remote branch to 15 m (50 ft) maximum.
- Keep the total KM BUS cable length to 50 m (164 ft) maximum.
- If additional KM BUS participants are present, connect them through the same terminal box as shown in the version 2 diagram.
If the unit shows an error code, look it up: Viessmann Boiler codes
Source: Viessmann Vitotronic 300-K MW1S installation and service instructions, p. 134-135. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.