Viessmann Boiler: Checking the room temperature sensor
Checking the room temperature sensor on a Viessmann boiler: The room temperature sensor measures the actual room temperature when the remote control cannot be installed in a suitable location. For connection, see pages 43 and 45.
Applies to: Room temperature sensor
Common causes of checking the room temperature sensor
- Severe deviation between sensor reading and actual room temperature may point to a wiring or installation fault, or a faulty sensor.
How to fix checking the room temperature sensor: step by step
- Disconnect the wires from the sensor.
- Measure the sensor resistance at terminals 9 and 13b.
- Compare the measured value with the actual room temperature shown on the display (scanning method on page 21).
- Check the installation if the deviation is severe.
- Replace the sensor if the installation is correct and the deviation is still severe.
If the unit shows an error code, look it up: Viessmann Boiler codes
Models
HK1BHK1MHK1SHK3SVitotrol 200Vitotrol 300
Source: Vitotronic 200-H installation and service instructions, p. 48. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.