Updated · by Aurora Star Tech Inc.

Check outdoor temperature sensor on a Viessmann boiler: Test the outdoor sensor resistance and compare it with the actual outdoor temperature.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Outdoor temperature sensor

Common causes of check outdoor temperature sensor

  • Sensor reads far from actual outdoor temperature
  • Faulty wiring or plug connection

How to fix check outdoor temperature sensor: step by step

  1. Remove plug and check sensor resistance at terminals 1 and 2.
  2. Compare with the resistance table for the measured temperature.
  3. Disconnect wires from the sensor if values deviate severely from the curve, then repeat the measurement.
  4. Compare with the actual outdoor temperature shown on the display.
  5. Replace the cable or the outdoor sensor depending on the result.
  6. Scan the actual temperature again.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Boiler codes

Models

HK1BHK1MHK1SHK3SVitotrol 200Vitotrol 300

Source: Vitotronic 200-H HK1M installation and service instructions, p. 36. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.