Viessmann Boiler: Change or scan the space heating time program
Change or scan the space heating time program on a Viessmann boiler: Set the on and off times for space heating phases. Scanning shows the preset phases without changing them.
Applies to: Vitotronic 200-H HK1S/HK3S, space heating time program
How to fix change or scan the space heating time program: step by step
- Open the hinged cover on the programming unit.
- Press the heating time program button (ur); the display changes to 'Exit? Yes' when you are in setting mode.
- Use the day selector to choose '1-7' for identical phases every day, or a single weekday (Mo, Tu, etc.) for different phases.
- Confirm, then set each phase's ON and OFF times with the up/down buttons and confirm each one.
- To exit at any time, press ur and confirm 'Exit? Yes'.
- Close the hinged cover.
If the unit shows an error code, look it up: Viessmann Boiler codes
Models
HK1BHK1MHK1SHK3SVitotrol 200Vitotrol 300
Source: Vitotronic 200-H operating instructions, p. 16. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.