Viessmann Boiler: Application example 1: one direct-connected heating circuit without mixing valve
Application example 1: one direct-connected heating circuit without mixing valve on a Viessmann boiler: Boiler controlled by Vitotronic 200 with one heating circuit that has no mixing valve. Optional domestic hot water tank. Single-stage burner is standard; two-stage or modulating burner needs the two-stage/modulating adaptor (included in standard boiler equipment). Power Pump Module supplies the heating circuit pump, boiler circuit and DHW pumps. Connections: outdoor sensor, boiler sensor, DHW tank sensor, KM-BUS participants, 120 VAC 60 Hz supply, and an optional low water cut-off device.
Applies to: Single heating circuit without mixing valve, with or without DHW tank
How to fix application example 1: one direct-connected heating circuit without mixing valve: step by step
- Connect the boiler temperature sensor, outdoor temperature sensor and DHW tank sensor (if fitted).
- Connect the heating circuit pump, boiler circuit pump and DHW pumps as shown for this layout.
- Connect the low water cut-off device if used.
- Connect KM-BUS participants through the KM-BUS Expansion Module where more than one KM-BUS cable is needed.
- Set the codings for this layout (see the coding tables for application example 1).
If the unit shows an error code, look it up: Viessmann Boiler codes
Models
HO1BKW2Vitotronic 200, type H01BVitotronic 200, Type HO1B
Source: Vitotronic 200 service instructions, p. 6. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.