Viessmann Boiler: Acknowledge maintenance display (Vitotronic 300-K)
Acknowledge maintenance display (Vitotronic 300-K) on a Viessmann boiler: The Vitotronic 300-K shows a maintenance message only when it is set as fault manager (coding 79:1) and a maintenance message is active on a connected Vitotronic 100.
Applies to: Vitotronic 300-K, MW1S
How to fix acknowledge maintenance display (vitotronic 300-k): step by step
- Press the scan button to open maintenance messages.
- Scan the messages with the up or down button.
- Press OK, then confirm the acknowledge prompt with OK.
- Acknowledge the matching message on the Vitotronic 100 (see page 89).
- If coding 24 on the Vitotronic 100 is not reset after maintenance, the message returns on the following Monday morning.
If the unit shows an error code, look it up: Viessmann Boiler codes
More reset & cancel tips for boiler
Source: Viessmann Vitotronic 100 GC1 / 300-K MW1S installation and service instructions, p. 94. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.