Viessmann Boiler: Acknowledge and reset maintenance messages (Vitotronic 100)
Acknowledge and reset maintenance messages (Vitotronic 100) on a Viessmann boiler: A maintenance message flashes once a set limit is reached. An acknowledged message can be shown again by holding the button for about 3 seconds. If maintenance is done before the message appears, the coding can be reset to clear the limits.
Applies to: Vitotronic 100, GC1
How to fix acknowledge and reset maintenance messages (vitotronic 100): step by step
- Scan the maintenance messages with the up or down button.
- Press OK to acknowledge the message. The display clears.
- After maintenance, set coding 24 to 1 and then back to 0 to reset run-hour and period limits.
- If required, reset burner run hours and starts from the scan screen.
- If required, reset max flue gas temperature with the reset combination shown on page 86.
- If coding 24 is not reset, a new message appears on Monday morning.
If the unit shows an error code, look it up: Viessmann Boiler codes
Models
More reset & cancel tips for boiler
Source: Viessmann Vitotronic 100 GC1 / 300-K MW1S installation and service instructions, p. 89. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.