Settings shortcuts: Air Handler tips
Short, practical technician tips on settings shortcuts for air handler. Check each one against the manual for your exact model before acting.
Airflow adjustment in Engineer Mode
Carrier · D5FUHA
Computational Constant Airflow adjusts fan speed and output to match ductwork, blocked coils and dirty filters. Air volume can be changed to customer needs through Engineer Mode on the remote or wired controller.
- Enter Engineer Mode on the wireless remote or the wired controller.
- Adjust the air volume setting as required for the customer.
- Check that airflow is adequate for the ductwork and filter in use.
CLEAN (self-cleaning) mode
Carrier · D5FS(L)AAH
Cleans and dries the evaporator in a 30-minute cycle, then shuts off. Works only in COOL or DRY mode. Pressing CLEAN mid-cycle cancels it and turns the unit off.
- Set the unit to COOL or DRY mode.
- Press CLEAN to start the cycle.
- Press CLEAN during the cycle to cancel and turn off.
CODE 22 heating temperature compensation
Carrier · D5FUHA remote controller, INQUIRY CODE 22
INQUIRY CODE 22 sets heating temperature compensation. Its default is 0. The manual gives -6 as the maximum DOWN range. It does not give the full allowable range or the upper limit.
- Enter INQUIRY mode and scroll to CODE 22.
- Enter SERVICE mode for CODE 22 and set the required compensation value.
- Exit SERVICE mode, exit INQUIRY mode, and power-cycle the outdoor unit for 3 minutes.
- Record the value set, because CODE 22 will show 0 on the next visit.
LED display light
Carrier · D5FS(L)AAH
Turns the display light on and off from the remote.
- Press LED on the remote.
SLEEP mode
Carrier · D5FUAAH air handler
Saves energy at night. Available in COOL, HEAT or AUTO only, and not in FAN or DRY.
- Press SLEEP on the remote.
- In COOL, the set point rises 2°F (1°C) after 1 hour and another 2°F (1°C) after a second hour, with fan on low speed.
- In HEAT, the set point drops by the same steps.
- Any press of MODE, TEMP, FAN, TIMER or ON/OFF cancels SLEEP.
SLEEP mode (remote, COOL/HEAT/AUTO)
Carrier · D5FS(L)AAH
SLEEP saves energy and works only in COOL, HEAT or AUTO. In COOL the setpoint rises 2°F (1°C) after 1 hour and another 2°F after a second hour, with low fan speed. In HEAT the setpoint drops by the same steps. The manual gives conflicting shutdown times (see notes). SLEEP cancels when MODE, TEMP, FAN, TIMER or ON/OFF is pressed on the remote.
- Press SLEEP on the remote while in COOL, HEAT or AUTO.
Sleep operation (remote only, not in FAN or DRY)
Carrier · D5FS(L)AAH
Sleep is only available from the remote and not in FAN or DRY mode. In COOL the temperature rises 2°F (1°C) after 1 hour and another 2°F after a second hour. In HEAT it drops by the same steps. Per this section, sleep stops after 8 hours and the system keeps running in its final state. This conflicts with the 5-hour figure on p. 16.
- Press SLEEP on the remote before going to sleep.
Timer ON and TIMER OFF
Carrier · D5FUAAH air handler
Starts or stops the unit at set times. Each can be used alone or together.
- Press TIMER ON (or TIMER OFF) to set the time. Each press adds 30 minutes up to 10 hours, then 60 minutes until 24 hours.
- When TIMER ON is set, the light on the unit comes on.
- To cancel, set the timer back to 0.0.
- To use both, set TIMER OFF and TIMER ON so the unit starts and stops at the chosen times.
- Keep the remote within 26 ft (8 m) of the unit when the timer is used.
Timer ON/OFF setting
Carrier · D5FS(L)AAH
Timer is set with the remote. For a unit that is off, set TIMER ON first then TIMER OFF, so it starts at the ON time and stops at the OFF time. For a unit that is on, set TIMER OFF first then TIMER ON, so it stops at the OFF time and starts at the ON time.
- Unit off: set TIMER ON, then set TIMER OFF.
- Unit on: set TIMER OFF, then set TIMER ON.
TURBO mode
Carrier · D5FUAAH air handler
Heats or cools the room quickly by running the fan at super high speed.
- Press TURBO. An audible beep confirms if the indoor unit supports it.
- Press TURBO again to end it immediately.
- TURBO ends automatically after 20 minutes and the unit returns to its previous setting.
Turn the indoor unit display LED on or off
Carrier · Wireless remote
The LED button turns the indoor unit display light and the buzzer on or off for a quieter room.
- Press LED on the remote to toggle the indoor display and buzzer.
Open air handler application settings
Navien · NPE-A2/S2 water heater with H2Air
Air handler (AHU) settings are in the application settings menu on the NPE-A2/S2 water heater.
- Open the Installer Menu and select 3. Application Settings.
- Select 3. Air handler Unit.
- Use the Up or Down button to move between parameters or change a value.
- Press OK to select a parameter or to confirm a change.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.