Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Other: Heat Pump tips (part 2 of 5)

Updated · by Aurora Star Tech Inc.

Short, practical technician tips on other for heat pump. Check each one against the manual for your exact model before acting.

Reading the non-ducted cooling performance tables

Carrier · D5CMHA non-ducted cooling tables, Tables 19-24

Each table is one size at one airflow. Find the outdoor DB row first, then the indoor WB group, then the indoor DB column. TC is total capacity, S/T is sensible-to-total ratio and PI is power input. Highlighted values are tested. Other values are simulated and for reference only.

  1. Pick the airflow block (CFM) that matches the indoor units installed.
  2. Find the outdoor dry-bulb row closest to the design condition.
  3. Go across to the indoor wet-bulb group, then to the indoor dry-bulb column.
  4. Read TC, S/T and PI from the same column.

Refrigerant circuit components

Carrier · D5CURA outdoor unit

The circuit has brass external liquid line service valves and suction line service valves, each with a service gauge port, plus an accumulator (heat pump units), a reversing valve and electronic expansion valves.

Refrigerant leak detection system operation

Carrier · Units with refrigerant sensor

When the sensor detects a leak, the indoor unit shows an error code and buzzes, the outdoor compressor stops at once and the indoor fan runs. The unit must stay powered except during service.

  1. Keep the unit powered except during service.
  2. Do not disable the leak detection system.

Remove compressor (terminal cover and pipes)

Carrier · All sizes

Before starting, remove the panel plate and the four-way valve connection on the PCB, using the size-specific panel plate procedures and the electrical parts section, then remove the sound blanket. Explosion risk: evacuate the system and confirm no refrigerant is left before removing the valve or compressor. For R32 and R290, evacuate with a vacuum pump, flush with nitrogen, and repeat before heating brazed parts. Only professionals should do these operations.

  1. Remove the flange nut of the terminal cover and remove the cover.
  2. Disconnect the connectors.

Remove electronic control board and 24V board

Carrier · Outdoor unit, size not stated on this page

Removal sequence for the outdoor control board and the 24V board subassembly. Steps 1 to 4 are not visible on the extracted page.

  1. Remove the 3 screws and take off the bracket.
  2. Disconnect the connectors from the electronic control board.
  3. Remove the 3 screws and take out the electronic control board.
  4. Pull out the connector, remove one screw, then remove the 24V board subassembly from the terminal board.

Remove four-way valve

Carrier · Heat pump models, all sizes

Before starting, remove the panel plate and the four-way valve connection on the PCB, using the size-specific panel plate procedures and the electrical parts section. Remove the sound blanket first. Fire hazard: evacuate the system and confirm no refrigerant is left before removing the valve or compressor. For R32 and R290, evacuate with a vacuum pump, flush with nitrogen, and repeat before heating brazed parts. Only professionals should do these operations.

  1. Heat the brazed joints and detach the four-way valve and the pipe.
  2. Remove the four-way valve assembly with pliers.

Remove outdoor fan and fan nut

Carrier · All sizes

Fan removal on all sizes. Use a spanner on the fan nut.

  1. Remove the nut that holds the fan, using a spanner.
  2. Remove the fan.

Remove outdoor fan motor

Carrier · All sizes

Fan motor removal on all sizes.

  1. Remove the 4 fixing screws of the fan motor.
  2. Remove the fan motor.

Remove sound blanket

Carrier · Models with sound blanket

Sound blanket removal. Applies only to models fitted with a blanket.

  1. Remove the side sound blanket.
  2. Remove the top sound blanket.

Replacing the control board fuse

Carrier · D5FSFAH control board

The control board has an overcurrent fuse. Its rating is printed on the board.

  1. Read the fuse rating printed on the board before replacing it. Examples printed include T3.15AL/250VAC, T5AL/250VAC, T3.15A/250VAC, T5A/250VAC, T20A/250VAC and T30A/250VAC.
  2. Use only the blast-proof ceramic fuse.

Room height and room area

Carrier · All units

The room height must be at least 7.3 ft (2.2 m). The minimum operating or storage room area depends on the charge amount listed in Table 1.

  1. Confirm the room height is at least 7.3 ft (2.2 m).
  2. Check the minimum room area for the unit's charge.

Routine cleaning and handling

Carrier · D5FUAA indoor unit

Basic care rules for the indoor unit.

  1. Clean with a soft cloth only; do not use harsh detergents or solvents.
  2. Do not touch the electrostatic filter if one is fitted.
  3. Do not open the inlet grille while the unit is running.
  4. Do not block the air inlet or outlet.
  5. Do not drink or touch drain water; check that the drain hose drains correctly.
  6. Use a firm step ladder when working on the unit.
  7. Lift with two or more people.

Wiring and power supply

Carrier · All units

Use only the specified wire and ground the product at installation. Connect and clamp cables tightly. Route wiring so the control board cover closes. Do not share the outlet with other appliances. Follow the Electrical Connection Diagram on the unit panels.

  1. Use the specified wire only.
  2. Ground the product.
  3. Clamp cables tightly.
  4. Route wiring so the board cover closes fully.
  5. Use a dedicated outlet.

Wiring cautions

Carrier · D5CURA wiring

Wiring mistakes can damage the outdoor and indoor control boards or cause a fire hazard.

  1. Make every wire connection firm; loose wiring can overheat the terminal.
  2. Keep all wire away from the refrigerant tubing, the compressor and moving parts.
  3. Route cable and conduit through the hole in the conduit panel.
  4. Follow local codes when running wire from the indoor unit to the outdoor unit.
  5. Provide a disconnect within sight of and readily accessible from the unit.
  6. Do not connect 24V AC to S1 - S2.

Accumulator can still be overwhelmed (Caution)

Generic

An accumulator protects against normal floodback, not massive low-side flooding — a badly overcharged or hunting system can still slug.

Biflow metering TXV bulb goes between reversing valve and compressor

Generic

With equalizer on the same line so it reads superheat in both modes.

Defrost "smoke" is steam

Generic

Warn new owners that the outdoor unit steaming in cold weather is normal defrost.

Dirty sock syndrome fix

Generic

Mold on indoor coil (HP heat not hot enough to kill it); UV germicidal light plus periodic pan/plenum chemical cleaning; shield plastic drain pans from UV.

Drain line flush

Generic

Blow out with air, prime trap, flush with 1:4 bleach:water.

Heat pump accumulators have smaller orifices

Generic

Don't substitute an AC accumulator; it won't throttle liquid return in winter.

Heat pump check valves bypass the idle metering device

Generic

Each TXV/piston works in one mode; the check valve routes flow around it in the other.

Ice around outdoor unit → check base-pan drain heat tape

Generic

Frozen drain means the pan heater is dead or missing.

Install outdoor unit on risers above snow line

Generic

8–18" typical; tell owner to keep snow clear.

Piston orifice size changes with line-set length

Generic

Manufacturers ship alternate pistons; long suction line sets may need a different orifice size. Heat pumps use two pistons (one meters each direction, the other free-flows through its flutes) or one piston outdoors + TXV with check-valve bypass indoors.

Record the LED code before anything else

Generic

Status LEDs flash codes keyed to the maker's table (example heat pump board: 1 = heartbeat, 2 = HPS open ≥6 s, 3 = discharge >263°F, 4 = discharge <90°F after 1 h run, 5 = defrost fail, 6 = discharge sensor short, 7 = outdoor sensor open/short, 9 = bonnet sensor fail).

Reversing valve energize state

Generic

In the book's example the solenoid is de-energized in cooling and energized in heating; the pilot uses discharge pressure to shift the piston. (Manufacturers vary — check the unit.)

Reversing valve identification

Generic

Lone stub = discharge; middle of three = suction. De-energized usually = heating.

Run every mode on a HP PM

Generic

Cooling, heating and defrost; a reversing valve that won't shift gets replaced.

Scroll/rotary vs recip for residential

Generic

Small hermetic recips and scrolls are chosen for homes because they're quiet, compact and need no service for years; scrolls have fewer parts, less vibration and can modulate via bypass port, variable speed or scroll-separation.

After refrigerant circuit damage: vent hydronic side

Viessmann · Vitocal 100-AW AM2V hydronic circuit

Refrigerant can get into the water side if the refrigerant circuit is damaged.

  1. After the work is finished, vent the hydronic system correctly.
  2. Make sure the area is well ventilated while venting.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977