Refrigerant line installation on a Viessmann mini-split: Lines are shipped with R410A charge on the outdoor unit. Buried lines need limits and a rise at the service valves.

Homeowner with a ductless mini-split problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: All 24K, 36K, 48K systems

How to fix refrigerant line installation: step by step

  1. Do not bury lines in the ground.
  2. If a line must be buried, keep the buried length to 36 in (914 mm) or less.
  3. Provide at least a 6 in (152 mm) vertical rise to the service valves to stop refrigerant migration.
  4. Insulate both lines with at least 1/2 in (12.7 mm) thick insulation.
  5. Use closed-cell insulation for long line runs.
  6. Isolate interconnecting tubing from the building structure so vibration and noise do not transfer.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Mini-Split codes

Source: Viessmann Vitocal IND-C ductless technical data manual, p. 7. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.