Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Viessmann Mini-Split: Electrical parts removal, sizes 48K-58K

Updated · by Aurora Star Tech Inc.

Electrical parts removal, sizes 48K-58K on a Viessmann mini-split: Steps to disconnect power and ground wires, remove the main control board and fan motor capacitors. Connections noted on the diagram: low and high pressure switch, T3 and T4, TP to indoor unit, and wires from the main board to the IPM module board.

Homeowner with a ductless mini-split problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: DLCLRC outdoor unit, sizes 48K and 58K (Models 48AAK, 58AAK)

How to fix electrical parts removal, sizes 48k-58k: step by step

  1. Remove the 2 screws to disconnect the power supply wires.
  2. Remove the 3 screws to disconnect the ground wires.
  3. Disconnect the wires connected to the main control board.
  4. Disconnect the wires between the main control board and the IPM module board.
  5. Remove the 4 screws and loosen the 6 hooks, then remove the main control board.
  6. Remove 1 screw per fan motor capacitor, then remove the capacitor.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Mini-Split codes

Source: DLCLRC service manual, p. 47. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service