Viessmann Mini-Split: Buried refrigerant pipe limits

Updated · by Aurora Star Tech Inc.

Buried refrigerant pipe limits on a Viessmann mini-split: Burying refrigerant pipe deeper or longer than allowed can let refrigerant migrate into the cold buried section during shutdown, causing slugging and possible compressor damage at start-up.

Homeowner with a ductless mini-split problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Refrigerant piping routed underground

How to fix buried refrigerant pipe limits: step by step

  1. Do not bury more than 36 in. (914 mm) of refrigerant pipe.
  2. If any pipe is buried, provide a 6 in. (152 mm) vertical rise to the outdoor unit valve connections.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Mini-Split codes

More commissioning tips for mini-split

Source: DLFSCBH and DLFLCBH installation instructions, p. 3. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.