Carrier Mini-Split: Two dashes (–) on the indoor display in multi-zone AUTO
Two dashes (--) on the indoor display in multi-zone AUTO on a Carrier mini-split: AUTO CHANGEOVER on multi-zone systems can put an indoor unit in STANDBY. Standby is shown as two dashes and turns that unit off until all units match mode.
Applies to: Multi-zone systems
Common causes of two dashes (--) on the indoor display in multi-zone auto
- AUTO mode used on a multi-zone system.
- Indoor units are in different modes (COOLING vs HEATING). HEATING is the system priority mode; simultaneous heating and cooling is not allowed.
How to fix two dashes (--) on the indoor display in multi-zone auto: step by step
- Set all indoor units to the same mode (COOLING or HEATING).
- Use AUTO only on single-zone systems.
- Confirm the dashes clear once all units match.
If the unit shows an error code, look it up: Carrier Mini-Split codes
Models
Source: D5FSFAH Owner’s Manual, p. 3. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.