Carrier Mini-Split: Select piping exit direction and knock-out panel
Select piping exit direction and knock-out panel on a Carrier mini-split: Four exit directions are available: left-hand side, left rear, right rear, and right-hand side. The drain hose is recommended on the right-hand side when facing the back of the unit. Side exits should come out horizontally so the lower panel can be installed.
Applies to: Indoor unit D5FSHA 6K to 36K
How to fix select piping exit direction and knock-out panel: step by step
- Choose the exit side based on the wall hole position relative to the mounting plate.
- If the wall hole is behind the unit, keep the knock-out panel in place.
- If the wall hole is at the side, remove the plastic knock-out panel on that side, using needle-nose pliers if needed.
- Cut the knock-out panel only as needed for the actual pipe size.
- Route the pipes so the unit sits against the wall after installation.
If the unit shows an error code, look it up: Carrier Mini-Split codes
Source: Carrier D5FSHA installation manual, p. 16. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.