Carrier Mini-Split: Refrigerant leak detected (units with sensor)
Refrigerant leak detected (units with sensor) on a Carrier mini-split: On units with a refrigerant sensor, a detected leak makes the indoor unit show an error code and buzz. The outdoor compressor stops right away and the indoor fan runs.
Applies to: Units with refrigerant sensor, R-454B
Common causes of refrigerant leak detected (units with sensor)
- Refrigerant leak at a joint or line set
- Refrigerant sensor detected leaked refrigerant
How to fix refrigerant leak detected (units with sensor): step by step
- Expect the indoor unit to show an error code and buzz; the outdoor compressor stops and the indoor fan keeps running.
- Keep the unit powered except during service.
- Remove or extinguish all open flames before searching for the leak.
- Find the leak with an electronic detector rated 1/8 oz (5 g) per year or better, or with leak detection fluid.
- Recover refrigerant from the system or isolate the leaking section with shut-off valves before any brazing.
If the unit shows an error code, look it up: Carrier Mini-Split codes
Source: Carrier D5FSOAH installation manual, p. 5-6. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.