Carrier Mini-Split: Refrigerant leak detected (units with sensor)

Updated · by Aurora Star Tech Inc.

Refrigerant leak detected (units with sensor) on a Carrier mini-split: On units with a refrigerant sensor, a detected leak makes the indoor unit show an error code and buzz. The outdoor compressor stops right away and the indoor fan runs.

Homeowner with a ductless mini-split problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Units with refrigerant sensor, R-454B

Common causes of refrigerant leak detected (units with sensor)

  • Refrigerant leak at a joint or line set
  • Refrigerant sensor detected leaked refrigerant

How to fix refrigerant leak detected (units with sensor): step by step

  1. Expect the indoor unit to show an error code and buzz; the outdoor compressor stops and the indoor fan keeps running.
  2. Keep the unit powered except during service.
  3. Remove or extinguish all open flames before searching for the leak.
  4. Find the leak with an electronic detector rated 1/8 oz (5 g) per year or better, or with leak detection fluid.
  5. Recover refrigerant from the system or isolate the leaking section with shut-off valves before any brazing.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Carrier Mini-Split codes

Source: Carrier D5FSOAH installation manual, p. 5-6. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977