Carrier Mini-Split: Mark the mounting plate and wall hole
Mark the mounting plate and wall hole on a Carrier mini-split: The wall hole size depends on the gas-side pipe size. A gas line of 5/8 in (16 mm) or larger needs a 3.54 in (90 mm) hole. A gas line smaller than 5/8 in (16 mm) needs a 2.5 in (65 mm) hole. The mounting plate has a bubble level that cannot be removed.
Applies to: Indoor unit mounting plate, D5FSHA 6K to 36K
How to fix mark the mounting plate and wall hole: step by step
- Remove the screw that holds the mounting plate to the back of the indoor unit.
- Fasten the mounting plate to the wall with the supplied screws, keeping it flat against the wall.
- Check the bubble level on the plate and keep the plate level.
- Use the plate ruler to locate the wall hole based on the plate position.
- For brick or concrete walls, drill 0.2 in (5 mm) holes and install the supplied sleeve anchors before tightening the plate screws.
- If the plate level bubble breaks, clean up any leaking liquid.
If the unit shows an error code, look it up: Carrier Mini-Split codes
Source: Carrier D5FSHA installation manual, p. 15. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.