Carrier Mini-Split: Limits for buried refrigerant piping
Limits for buried refrigerant piping on a Carrier mini-split: Do not bury more than 36 in. (914 mm) of refrigerant pipe. If any pipe is buried, the pipe must rise at least 6 in. (152 mm) to the outdoor unit valve connections.
Applies to: Refrigerant piping installation
How to fix limits for buried refrigerant piping: step by step
- Keep buried refrigerant pipe to 36 in. (914 mm) or less.
- Make a 6 in. (152 mm) vertical rise to the outdoor unit valves if any pipe is buried.
If the unit shows an error code, look it up: Carrier Mini-Split codes
Models
45MBCAQ12XA3D5FLCAH36XAKD5FLCAH48XAKD5FSCAH12XAKD5FSCAH18XAKD5FSCAH24XAK
More other tips for mini-split
Source: D5FSCAH / D5FLCAH service manual, p. 1. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.