IPM continuity check on a Carrier mini-split: Checks the IPM module by measuring diode-type resistance between the module terminals. Electricity can stay in the capacitors after power-off, so discharge them first.

Homeowner with a ductless mini-split problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: D5FSFAH outdoor unit IPM module

How to fix ipm continuity check: step by step

  1. Turn off the outdoor unit and disconnect the power supply.
  2. Discharge the electrolytic capacitors and make sure all stored energy is gone.
  3. Disassemble the outdoor PCB or the IPM board.
  4. Measure resistance between P and U, V, W and N, and between U, V, W and N as shown in Fig. 25.
  5. Compare readings with Table 7; the table values are not legible in the text, so use the manual's Table 7 directly.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Carrier Mini-Split codes

Models

D5FSFAH09XAKD5FSFAH12XAKD5FSFAH16XAK

Source: Carrier D5FSFAH service manual, p. 36. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977