Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Carrier Mini-Split: Downsize D5FSOAH12XAK from 12K to 9K

Updated · by Aurora Star Tech Inc.

Downsize D5FSOAH12XAK from 12K to 9K on a Carrier mini-split: The D5FSOAH12XAK is dual capacity and ships at 12K. ENC1 on the main board sets it to 9K.

Homeowner with a ductless mini-split problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: D5FSOAH12XAK

How to fix downsize d5fsoah12xak from 12k to 9k: step by step

  1. Disconnect power.
  2. Open the electronic control box.
  3. Set ENC1 to 2.
  4. Close the electronic control box.
  5. Reconnect power. The unit now runs as 9K.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Carrier Mini-Split codes

More other tips for mini-split

Source: D5FSOAH service manual, p. 14. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977