Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Carrier Mini-Split: Ceiling cassette panel installation

Updated · by Aurora Star Tech Inc.

Ceiling cassette panel installation on a Carrier mini-split: Fit the one-way cassette panel into the ceiling opening and connect the display board.

Homeowner with a ductless mini-split problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Cassette panel fitting for D5FSOAH indoor units

How to fix ceiling cassette panel installation: step by step

  1. Cut the ceiling opening to 16.93 x 51.18 in (430 x 1300 mm), centred on the indoor unit body, and reinforce the ceiling if needed to avoid vibration.
  2. Remove the installation board after the ceiling is cut.
  3. Open the two screw covers and remove the two screws. Close the covers after the final screws are fixed.
  4. Open the air grille, push both latches to the middle to unlock it, and remove the panel grille.
  5. Secure the cassette panel to the one-way cassette with the two plastic straps.
  6. Rotate the louver by hand, then fix the panel with 3 x M4x22 screws and one ST3.9x16 screw.
  7. Open the covers on both sides of the panel and fix the rest of the M4x22 screws.
  8. Connect the display board to the main control board. Match the wire colours to the pins, and clip the wires to the strap.
  9. Install the control box cover, set the disconnect switch to ON, then close the side covers.
  10. Re-install the air grille by pushing the latches to lock, secure the two screws and close the covers.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Carrier Mini-Split codes

Source: D5FSOAH installation instructions, p. 21-22. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977