Carrier Mini-Split: Auto-restart after power failure
Auto-restart after power failure on a Carrier mini-split: An auto-restart module stores the last settings. After power returns, the unit resumes the previous settings (SWING excluded) after 3 minutes. If forced cooling was stored, the unit runs cooling 30 minutes then AUTO at 75°F (24°C). If the unit was off and must start, the compressor waits 1 minute; otherwise it waits 3 minutes.
Applies to: D5FCFAH
How to fix auto-restart after power failure: step by step
- Confirm DIP/menu auto-restart setting is active if the unit must resume after outages.
- Allow 3 minutes after power returns before expecting restart.
If the unit shows an error code, look it up: Carrier Mini-Split codes
Models
D5FCFAH18XAKD5FCFAH24XAKD5FCFAH36XAKD5FCFAH48XAKD5FCFAH58XAKD5FCFH18XAKD5FCFH24XAKD5FCFH36XAKD5FCFH48XAKD5FCFH58XAKD5SCHA
More other tips for mini-split
Source: D5FCFAH service manual, p. 19. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.