Carrier Mini-Split: 24K/36K/48K: evaporator and refrigerant sensor removal
24K/36K/48K: evaporator and refrigerant sensor removal on a Carrier mini-split: Removes the pipe clamp board, refrigerant sensor, evaporator fixing board and then the evaporator with its hangers.
Applies to: 24K/36K/48K size indoor units
How to fix 24k/36k/48k: evaporator and refrigerant sensor removal: step by step
- Remove the 2 screws of the pipe clamp board.
- Remove the 2 screws and take out the refrigerant sensor.
- Remove the 2 screws of the evaporator fixing board and remove it.
- Remove the 2 screws of the evaporator fixing hangers and remove the evaporator.
If the unit shows an error code, look it up: Carrier Mini-Split codes
Source: D5FSCAH / D5FLCAH service manual, p. 76. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.