Daikin Air Conditioner: FIT: reading the fault code and fault history
FIT: reading the fault code and fault history on a Daikin air conditioner: How to read the present fault and the last six faults on the 3-digit outdoor board display.
Applies to: DC6VS***1*A*, DC9VSA[24-48]10A* (FIT and Enhanced Capacity/High Efficiency FIT)
How to fix fit: reading the fault code and fault history: step by step
- Screen 0 (default) shows the present fault.
- Hold RECALL 5 seconds to go to Screen 1 (fault history).
- Press RECALL to step through the last six faults, newest first.
- Press LEARN to go back to Screen 0.
- Look up each code in the troubleshooting table.
If the unit shows an error code, look it up: Daikin Air Conditioner codes
Models
DC6VS*181DC6VS*241DC6VS*301DC6VS*361DC6VS*421DC6VS*481DC6VS*601DC9VSA2410DC9VSA3610DC9VSA4810
Source: Daikin 3P761829-1B FIT outdoor unit installation & service reference, Setting the Mode Display p.48-50 and 7-Segment Display Screen 0/1 p.54 (printed pages). Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.