Short, practical technician tips on other for mini-split. Check each one against the manual for your exact model before acting.

Installation clearances and site limits

Carrier · D5FSOAH indoor and outdoor units

Keep clearances from combustibles and keep the unit level, firm and free of obstructions.

  1. Keep an auxiliary electric heater unit at least 3 ft (1 m) from any combustible materials.
  2. Confirm the support can hold the unit weight before installing.
  3. Keep the unit level and secured.
  4. Keep ventilation openings and air inlets and outlets clear of obstruction.
  5. Install drain hoses so water drains correctly.
  6. Use two or more people to lift or move the unit.
  7. Disconnect power or turn off the breaker when the unit will be idle for a long time.

Keep outdoor unit powered in cold weather

Carrier · Outdoor units with crankcase heater

Below 32 F (0 C) the crankcase heater on the outdoor unit must stay energized to prevent compressor damage.

  1. Keep the outdoor unit powered at all times when outdoor temperature is below 32 F (0 C).

Limits for buried refrigerant piping

Carrier · Refrigerant piping installation

Do not bury more than 36 in. (914 mm) of refrigerant pipe. If any pipe is buried, the pipe must rise at least 6 in. (152 mm) to the outdoor unit valve connections.

  1. Keep buried refrigerant pipe to 36 in. (914 mm) or less.
  2. Make a 6 in. (152 mm) vertical rise to the outdoor unit valves if any pipe is buried.

Lock out power before any install or service

Carrier · All installation and service work

Turn off the main electrical disconnect before installing, modifying or servicing. There may be more than one disconnect.

  1. Switch off the main disconnect.
  2. Check for any additional disconnects.
  3. Lock out and tag all disconnects before working.

Louver position memory

Carrier · D5FSFAH 9K to 16K

On restart the louver returns to the angle the user set, if that angle is within the allowed range. If the angle is out of range, the unit stores the maximum allowed angle. After a power failure or a TURBO shutdown the louver returns to its default angle.

Louver swing and feature availability

Carrier · Units with louver swing

The horizontal louver swing is started and stopped with the SWING button. The manual says vertical auto swing is available by holding the same button for 2 seconds on some units.

  1. Press SWING to start or stop horizontal louver movement.
  2. On units that support it, hold SWING for 2 seconds for vertical auto swing.

Meaning of unit symbols

Carrier · Indoor and outdoor units

Warning symbol: flammable refrigerant is used, so there is a fire risk if it leaks near an ignition source. Caution symbol: read the operation manual carefully. Caution symbol: service personnel must handle the equipment using the installation manual. Information symbol: the operating or installation manual has more information.

Minimum room height and area for flammable refrigerant

Carrier · Indoor units with R-454B refrigerant

Room height must be at least 7.3 ft (2.2 m). The minimum room area depends on the refrigerant charge and release height, using the tables for the unit.

  1. Check that the room is at least 7.3 ft (2.2 m) high.
  2. Find the minimum room area from the charge and release height table for the unit.
  3. Make sure the room area of operation or storage matches the table.
  4. Keep ventilation openings clear of obstruction.

Multi-zone AUTO mode caution

Carrier · Multi-zone systems

AUTO changeover is recommended for single-zone systems only. On multi-zone systems, an indoor unit can drop into STANDBY and show two dashes (--) until all indoor units run in the same mode, either COOLING or HEATING.

Operating modes

Carrier · All operating modes

Five modes: FAN Only, AUTO, HEATING (heat pumps only), COOLING, and DEHUMIDIFICATION. HEATING is the priority mode, and simultaneous heating and cooling is not allowed. In multi-zone systems, AUTO can put a unit into STANDBY, shown as two dashes (--), until all indoor units run the same mode.

  1. Use AUTO on single-zone systems only.
  2. On multi-zone systems, expect '--' on the display when a unit is in STANDBY; all units must be in the same mode, either COOLING or HEATING.
  3. Dehumidification (DRY) reduces humidity and slightly cools the room. It does not replace a dehumidifier.

Operating modes overview

Carrier · D5FSFAH floor console ductless system

The unit has five modes: FAN Only, AUTO, HEATING, COOLING and DEHUMIDIFICATION (DRY).

  1. Use AUTO only on single-zone systems; on multi-zone systems AUTO can put an indoor unit in STANDBY (shown as --).
  2. HEATING is the priority mode; simultaneous heating and cooling is not allowed.

Optional 24V interface for third-party control

Carrier · D5FSHA systems

An optional 24V interface lets a third-party thermostat control the ductless system.

  1. Install the 24V interface if a third-party thermostat must control the system.

Optional Wi-Fi kit for smart phone control

Carrier · D5FSHA systems

The Wi-Fi kit lets the system be controlled from a connected smartphone app.

  1. Install the Wi-Fi kit (P/N KSAIF0701AAA) to enable smartphone control.

Outdoor heat pump compressor time delay

Carrier · Heat pump outdoor units

The outdoor condensing unit on heat pumps has a three-minute time delay before the compressor starts. Over-current and high temperature protection are also covered by this delay.

  1. Allow about three minutes before expecting the compressor to start after a restart.

Outdoor unit control compartment and coil cleaning

Carrier · Outdoor condensing units

Removing the top panel on the outdoor unit gives direct access to the control compartment. The draw-thru design means dirt collects on the outside of the coil.

  1. Remove the top panel of the outdoor unit to reach the control compartment.
  2. Clean the coil from the inside using a pressure hose and detergent.

Outside air output (CN8)

Carrier · D5FSCAH / D5FLCAH indoor unit

Output for energising an outside air fan through a relay.

  1. Output is 208/230 VAC. Do not exceed 1 A (200 W).
  2. Power is on when the indoor fan runs and off when the indoor fan stops.
  3. No power on CN8 during force cooling or capacity test mode.
  4. Use a separate power supply for the outside air fan. CN8 should only drive a relay coil.

Parts the installer must buy separately

Carrier · D5FSOAH indoor unit installation

Several items are not supplied with the indoor unit: outdoor unit power cable, connection cable, drain pipe, refrigerant piping and the remote controller holder. An additional circuit breaker is also required for the installation.

  1. Buy the outdoor power cable, connection cable, drain pipe, refrigerant piping and remote controller holder separately.
  2. Fit an additional circuit breaker for the indoor unit.

PCB fuse replacement

Carrier · Indoor and outdoor control boards

The control board has an overcurrent fuse. Its rating is printed on the board (examples: T3.15AL/250VAC, T5AL/250VAC, T20A/250VAC, T30A/250VAC).

  1. Replace only with a blast-proof ceramic fuse matching the rating printed on the board.

Performance and energy tips for the customer

Carrier · Indoor unit

Basic steps that help the unit run efficiently.

  1. Keep doors and windows closed.
  2. Use TIMER ON and TIMER OFF to limit energy use.
  3. Do not block air inlets or outlets.
  4. Inspect and clean air filters regularly.
  5. Replace the air filter every 30 to 90 days, depending on thickness and MERV rating.
  6. Do not set the temperature to excessive levels.
  7. Close curtains in cooling to block direct sun, and keep them closed in heating to hold heat in.
  8. Do not place objects near the air inlet or outlet.

Point the remote at the right side of the unit

Carrier · D5FCFAH wireless remote controller

Commands must be sent toward the right side of the indoor unit. The unit confirms receipt with an audible beep. The remote works up to 26 ft (8 m) away without obstructions.

  1. Point the remote toward the right side of the indoor unit when sending commands.
  2. Stay within 26 ft (8 m) with no obstructions, and within range of the unit when using the timer.

Power supply, wiring and protection requirements

Carrier · D5FSOAH indoor and outdoor units

Fixed wiring needs an all-pole disconnect and a residual current device. Use only the specified wire and dedicated circuit.

  1. Use only the specified wire. If the wire is damaged, have it replaced by the manufacturer, its service agent or a similarly qualified person.
  2. Ground the product at installation.
  3. Use an all-pole disconnect with at least 3 mm contact clearance on all poles, in the fixed wiring.
  4. Use a residual current device rated at no more than 30 mA where leakage current may exceed 10 mA.
  5. Use a dedicated circuit and breaker. Do not share the outlet. Do not use defective or under-rated breakers.
  6. Do not modify or extend the power cable.
  7. Wire all connections to the Electrical Connection Diagram on the indoor and outdoor unit panels.
  8. Route wiring so the control board cover closes fully, and clamp cables so the terminals are not stressed.

Power-on buzzer check

Carrier · Indoor unit

Every time the unit is powered on, it should give a buzzing sound to show it powered on normally. No sound may mean a malfunction.

  1. If there is no buzz at power-on, power the unit on again or check the circuit.

Pre-season inspection checklist

Carrier · Indoor and outdoor units

Run this check after long periods of non-use or before frequent use.

  1. Run the FAN function until the unit dries out completely.
  2. Clean all filters.
  3. Check for damaged wires.
  4. Check for leaks.
  5. Make sure nothing blocks the air inlets and outlets.

Protect piping while bending

Carrier · D5FSHA sizes 6K to 36K

Dents in the refrigerant piping reduce unit performance.

  1. Grip the pipe at the base of the bend.
  2. Bend slowly with even pressure toward the hole.
  3. Do not dent or damage the piping.

R-454B flammable refrigerant (A2L)

Carrier · D5FCFA system

The system uses R-454B, safety group A2L. Follow the handling instructions and national regulations.

  1. Handle R-454B per the handling instructions.
  2. Follow national regulations for refrigerant work.

Recover and purge refrigerant

Carrier · All D5FCFAH units

Recovery and purging must follow the flammable refrigerant rules. Recovered refrigerant must not be mixed or reused without cleaning and checking.

  1. Recover the refrigerant into labeled recovery cylinders with a pressure-relief valve.
  2. Do not fill any cylinder above 80% of its liquid volume.
  3. Keep cylinders upright and do not exceed their maximum working pressure.
  4. Purge the circuit with oxygen-free nitrogen. Do not use compressed air or oxygen.
  5. Vent to atmospheric pressure before opening the circuit to work.

Refrigerant leak detection codes (Table 4)

Carrier · Units with refrigerant sensor

If you see a refrigerant leak detection code, the unit goes into TURBO mode until the code clears, and a beeping sound from the indoor unit is normal.

  1. Call a technician as soon as possible.
  2. Do not be alarmed by the beeping or TURBO operation; both are normal with this code.

Refrigerant leak detection system

Carrier · Units with refrigerant sensor

The unit has a leak detection system and must stay powered except during service. When a sensor detects a leak, the indoor unit shows an error code and beeps, the outdoor compressor stops immediately and the indoor fan runs. The sensor life is 15 years. A failed sensor shows FHCC and must be replaced by the manufacturer with the specified sensor.

  1. Keep the unit powered except during service.
  2. Call a technician as soon as possible if a leak code appears.

Refrigerant leak mitigation sensor

Carrier · Indoor units, sizes 06 to 36

The indoor unit is equipped with a refrigerant leak detection sensor as standard. Diagnostics warn of possible malfunctions and show error messages on the unit.

Refrigerant pipe burial limit

Carrier · Field refrigerant piping

Burying too much refrigerant pipe lets liquid refrigerant migrate into the buried section during shutdown, which can cause slugging and compressor damage at start-up.

  1. Do not bury more than 36 in (914 mm) of refrigerant pipe.
  2. If any section is buried, provide a 6 in (152 mm) vertical rise to the outdoor unit valve connections.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.