Other: Air Handler tips (part 1 of 6)

Updated · by Aurora Star Tech Inc.

Short, practical technician tips on other for air handler. Check each one against the manual for your exact model before acting.

115V conversion

Carrier · D5FUAA air handler

The unit can be converted to 115V applications.

24 V communication prohibited

Carrier · D5FUAA

24 V communication between indoor and outdoor units is not allowed for compliance reasons. Do not connect 24 V AC to S1-S2; this will damage the system.

  1. Check the wiring nameplate before wiring.
  2. Never connect 24 V AC to S1 or S2.

Active clean (self-clean) cycle

Carrier · D5FUAAH air handler

Cleans and dries the evaporator automatically.

  1. Press CLEAN to start. The function works only in COOL or DRY mode.
  2. The cycle runs about 30 minutes, then the unit turns off automatically.
  3. Press CLEAN during the cycle to cancel and turn the unit off.

Adding refrigerant on long pipe runs

Carrier · D5FUAA with extra pipe length

Standard pipe length in North America is 25 ft (7.5 m). Charge any extra refrigerant from the service port on the outdoor unit low pressure valve. Refer to the outdoor unit manual for the amount.

Air filter replacement interval

Carrier · Indoor unit air filter

The filter should be replaced every 30 to 90 days depending on its thickness and MERV rating. The user must buy a standard filter that meets UL900.

  1. Replace the filter every 30 to 90 days, based on filter thickness and MERV rating.
  2. Inspect and clean or replace the filter monthly or as needed.
  3. Use only a standard filter that meets UL900.

Air filter requirement

Carrier · D5FSAA / D5FLAA air handler

The filter is not supplied. The installer must provide a standard filter that meets UL900. Ask the manufacturer if you need help choosing one.

  1. Fit a UL900 standard filter.

Air outlet height in room

Carrier · Ducted room outlets

Where the unit connects to one or more rooms by air duct, the bottom of the duct air outlet in the room must be at a height of 7.3 ft (2.2 m) from the floor.

  1. Set the bottom of the room air outlet at 7.3 ft (2.2 m) above the floor.

Alarm output (CN33)

Carrier · D5FUAA indoor unit

Passive relay output. Relay is normally open in normal operation and closes when a fault is active. An external voltage signal must be supplied.

  1. Wire the alarm device to CN33 and supply the voltage signal needed for the device.

Auto defrost in HEAT mode

Carrier · D5FS(L)AAH

When the outdoor coil frosts in HEAT mode, the indoor and outdoor fans turn off while the frost is removed. Normal operation resumes automatically.

Auto-restart after power failure

Carrier · D5FSAA indoor units

The indoor unit stores its current settings. After a sudden power loss, it restores those settings automatically within 3 minutes of power returning.

  1. After a power failure, allow up to 3 minutes for the unit to restore its previous settings.
  2. If settings do not return, check the power supply and the indoor unit's auto-restart module.

Automatic restart after power failure

Carrier · D5FUAA crossover air handler

After a power failure the unit returns to the same operating conditions it had when power was lost.

Built-in 24V interface and controls

Carrier · D5FUAA air handler

A built-in 24V interface allows a third-party thermostat to control the system. The unit has microprocessor controls, cleanable filters, and built-in diagnostics. Freeze protection and high temperature protection on the heat pump are standard.

Built-in control functions

Carrier · D5FUHA indoor air handler

The indoor control includes several protection and operating functions.

  1. After a power failure, the unit returns to the operating condition it had when power was lost.
  2. Heat pump mode switches automatically between heating and cooling, with a deadband to prevent rapid cycling.
  3. Indoor coil freeze protection and high coil temperature protection are active in heat pump mode.
  4. Self diagnostics display error messages on the unit.

Buried refrigerant pipe limits

Carrier · Refrigerant line routing

No more than 36 in. (914 mm) of refrigerant pipe may be buried. If any section is buried, there must be a 6 in. (152 mm) vertical rise to the outdoor unit valve connections.

  1. Limit buried refrigerant pipe to 36 in. (914 mm).
  2. Provide a 6 in. (152 mm) vertical rise to the outdoor valve connections where any pipe is buried.

Charging and leak test rules

Carrier · Flammable refrigerant systems

Requirements for charging flammable refrigerant systems.

  1. Use tools suitable for flammable refrigerants and keep hoses as short as possible.
  2. Keep cylinders upright.
  3. Earth (ground) the refrigeration system before charging.
  4. Label the system when charging is complete.
  5. Do not overfill the system.
  6. Pressure test with oxygen-free nitrogen before recharging.
  7. Leak test after charging and before commissioning, and again before leaving the site.

Charging and recharging requirements

Carrier · Refrigerant charging

Use only tools suited to flammable refrigerant. Keep hoses short and avoid cross-contamination. Keep cylinders upright. Earth the system before charging. Do not overfill. Pressure test with OFN before recharging. Leak test after charging and again before leaving the site. Label the system when charging is done.

  1. Use tools and hoses suited to flammable refrigerant, kept as short as possible.
  2. Keep cylinders upright and earth the system before charging.
  3. Do not overfill the system.
  4. Pressure test with OFN before recharging.
  5. Leak test after charging and before commissioning, and again before leaving the site.
  6. Label the system when charging is complete.

Check outdoor unit match and sizing before installing

Carrier · D5FUHA indoor unit

Confirm the indoor unit is compatible with the outdoor unit using the product data. Confirm the application and run a heat load calculation for proper sizing.

  1. Check indoor and outdoor unit compatibility in the product data.
  2. Confirm the application and complete a heat load calculation.

Circuit board fuse replacement

Carrier · D5FULA crossover evaporator coil, sizes 24K - 60K

The circuit board has an overcurrent fuse. The rating is printed on the board. Only a blast-proof ceramic fuse may be used.

  1. Read the fuse rating printed on the circuit board.
  2. Replace only with a blast-proof ceramic fuse of the same rating.

Clean the indoor unit with approved methods only

Carrier · Indoor unit cleaning and maintenance

Turn off the unit and disconnect power before cleaning. Use a soft dry cloth or a damp lint-free cloth with neutral detergent. Do not use solvents, benzene, chemical cloths, running water or water above 104°F (40°C) on the front panel. Replacement fuses must match the removed fuse exactly.

  1. Turn off the unit and disconnect the power supply.
  2. Wipe with a soft dry cloth, or a damp lint-free cloth with neutral detergent.
  3. Do not use solvents, chemicals, combustible cleaners or running water.
  4. Keep water on the front panel below 104°F (40°C).
  5. Replace a blown fuse only with an identical fuse rating.

Cleaning precautions

Carrier · D5FULA indoor coil

Only untrained personnel should do basic cleaning such as coil cleaning. Cut power before cleaning. Do not use excessive water or combustible cleaning agents.

  1. Turn off the device and disconnect power.
  2. Do not flood the unit with water.
  3. Do not use combustible cleaning agents.

Cleaning the air filter

Carrier · D5FS(L)AAH

Inspect and clean or replace the filter monthly or as needed. Clean by vacuuming or washing in warm water with mild detergent. Do not dry in direct sunlight, as the filter can shrink.

  1. Turn off the unit and disconnect power.
  2. Remove the filter cover.
  3. Remove the air filter.
  4. Vacuum the filter or wash it in warm water with mild detergent.
  5. Let it dry out of direct sunlight and reinstall.

Clear the air outlet before installing

Carrier · D5FSAA / D5FLAA air handler, 18-60K

Remove all accessories and packing material from the air outlet before mounting the indoor unit.

  1. Remove all accessories and packing from the air outlet.
  2. Do this before the unit is put in place.

Clearance and location limits

Carrier · Indoor unit installation

Location rules for the air handler.

  1. For units with an auxiliary electric heater, keep the unit at least 1 m (3 ft) from combustible materials.
  2. Do not install the unit where combustible gas leaks may collect.
  3. Install on a firm surface that can carry the unit weight.
  4. Install drain piping per the manual to avoid water damage.
  5. Do not turn on power until all work is complete.

Clearance from combustible materials

Carrier · Units with auxiliary electric heater

For units with an auxiliary electric heater, do not install the unit within 3 ft (1 m) of combustible materials.

  1. Keep at least 3 ft (1 m) between the unit and any combustible materials when an auxiliary electric heater is fitted.

Clearance from combustibles for units with auxiliary heater

Carrier · Units with auxiliary electric heater

Units with an auxiliary electric heater must be kept at least 3 ft (1 m) from combustible materials.

  1. Keep units with auxiliary electric heater at least 3 ft (1 m) from combustible materials.

Compressor time delay after stop

Carrier · D5FS(L)AAH

If ON/OFF is pressed soon after a stop, the compressor will not start for 3 to 4 minutes to protect against frequent cycling. The unit beeps only when the signal is received correctly.

Condensate drain requirements

Carrier · D5FSAA / D5FLAA air handler

Route the drain so water cannot leak onto the building or create icy walkways. A water leak can cause a water-level switch fault.

  1. Insulate all piping to prevent condensation.
  2. Slope and route the drain pipe so water drains away from the unit without bends or wrong installation.
  3. Place the drain outlet away from walkways because the outdoor unit discharges water in heat mode.
  4. Do not pull the drain pipe hard, because it can come loose.
  5. Seal around the drain pipe, liquid line and suction line to keep humid air out.

Control board fuse

Carrier · Indoor and outdoor control boards

The control board has a fuse for overcurrent protection. The rating is printed on the board, for example T3.15AL/250VAC, T5AL/250VAC, T3.15A/250VAC, T5A/250VAC, T20A/250VAC or T30A/250VAC. Only a blast-proof ceramic fuse may be used.

  1. Read the rating printed on the board.
  2. Replace only with a blast-proof ceramic fuse of the same rating.
  3. Power off and disconnect before replacing.

Control board fuse replacement

Carrier · Indoor unit control PCB

The board is protected by a fuse. The rating is printed on the circuit board (examples given: T3.15AL/250VAC, T5AL/250VAC, T3.15A/250VAC, T5A/250VAC, T20A/250VAC, T30A/250VAC). Only a blast-proof ceramic fuse may be used.

  1. Read the fuse rating printed on the circuit board.
  2. Replace with the same rating in a blast-proof ceramic fuse only.

Control options and compatibility

Carrier · D5FUAAH

The unit can be run from the included wireless remote, the optional wired controller, or a third-party 24V heat pump thermostat. The wired controller and wireless remote cannot be used together with a third-party thermostat. If the remote is lost, the unit can be run from the Auto setting on the unit.

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.