Access & passwords: Boiler tips (part 2 of 4)
Short, practical technician tips on access & passwords for boiler. Check each one against the manual for your exact model before acting.
Call up the extended menu
Viessmann · Vitodens 200-W B2HB with Vitotronic control
The extended menu holds less-used settings such as time and holiday programs. Some key symbols did not extract cleanly from this page.
- If the screen saver is on, press any key except the help key, then press the key shown in the manual.
- If you are already in the menu, press the key shown in the manual.
- To return to the standard menu, keep pressing until it appears.
Calling up coding level 1
Viessmann · Vitotronic 200-H HK1B
Coding level 1 is opened from the control unit and holds the heating circuit, General, DHW and Solar code groups.
- Press OK together with the second control key shown in the manual for about 4 seconds (key symbol not legible in this text).
- Select the coding level 1 entry.
- Select the group needed: General, DHW, Solar, Heating circuit 1/2/3, or All codes standard unit.
- Select the coding address, choose the value from the tables and confirm with OK.
- To reset all codes to factory settings, choose Standard setting in coding level 1; this also resets coding level 2.
Calling up coding levels
Viessmann · Vitocrossal 300 CA3B Dual Fuel Series 2.5 to 6.0
Coding is grouped by General, Burner control unit, DHW, Solar, Heating circuit 1/2/3, Boiler, Cascade and All coding. Level 1 uses the viservice password; level 2 uses viexpert.
- From the home screen tap Menu.
- Tap Service.
- Enter the viservice password.
- Tap System configuration.
- Tap Coding level 1, or Coding level 2 and enter the viexpert password.
Calling up the extended menu
Viessmann · Vitodens 200-W B2HA 112/150/399/530
The extended menu holds less frequently used settings such as time programs and holiday programs. The screen saver turns on after a few minutes without input and dims the display.
- If the screen saver is active, press any key except the ? key, then press the key shown in the manual.
- If you are already somewhere in the menu, press the key shown in the manual to go to the extended menu.
- To return to the standard menu from a zone circuit display, keep pressing the key until the standard menu appears.
Calling up the main menu
Viessmann · Vitotronic 300-K, MW2C cascade control
The main menu lets you change the boiler sequence and scan or change cascade settings. It can be reached from the screensaver or from any menu level.
- If the screensaver is on, tap the display, then tap the menu button.
- From any other menu level, tap the menu button.
- Use the footer buttons to go back a level or return to the home screen.
Calling up the service level
Viessmann · Vitodens 200-W B2HA 19, 28, 35
Opens the service menu used for diagnosis, resets, brief scan and coding. The button symbol is missing in the manual text, so read the button from the controller.
- Press OK and the second button shown on the controller at the same time for about 4 seconds.
Change service or coding passwords
Viessmann · Vitocrossal 300 CA3B Series 2.5 to 6.0
Service level and Coding level 2 passwords can be changed by the installer. A forgotten or lost password can only be reset with a master password, which must be requested from Viessmann Technical Service.
- From the home screen tap Service and enter the viservice password.
- Select Change passwords, then choose Service level or Coding level 2.
- Enter the current password and confirm.
- Enter the new password and confirm.
Change the lock panel password
Viessmann · Control panel
New password is 1 to 20 characters. No confirmation of the new password is required.
- Open Settings.
- Select 'Change password'.
- Enter the current password and confirm.
- Enter the new password and confirm.
- Confirm the prompt.
Change the service menu password
Viessmann · Vitocrossal 200 CI2 service menu
Factory service password is viservice. Change it after first access.
- Tap the first button shown in the manual (symbol not readable in extracted text).
- Tap Service.
- Enter password viservice and confirm.
- Tap Change passwords.
- Tap Service menu.
- Enter current password and confirm.
- Enter new password.
- Confirm the new password twice.
Change the service or coding level 2 password
Viessmann · Vitotronic 300 GW6B boiler control unit
Factory passwords are viservice for the service main menu and viexpert for coding level 2. Enter the current password before setting a new one.
- From the home screen, tap Menu, then Service.
- Enter the viservice password.
- Tap Change passwords.
- Choose Service level or Coding level 2.
- Enter the current password and confirm with OK.
- Enter the new password.
- Tap OK twice.
Coding addresses
Viessmann · Vitodens 200-W B2HA 112/150/399/530
Coding address changes are used to match parameters to the installed system. The coding addresses named in fault codes (e.g. A3, 30, 52:0) are set in the coding levels.
Do not change Multi-boiler system
Viessmann · Vitotronic 200 and 300-K service level
This item changes a weather-compensated control into a constant temperature control. Leave it unchanged unless the control type is meant to change.
- Do not adjust the "Multi-boiler system" item in the service menu.
Enter advanced (extended) parameter settings
Viessmann · Vitotron 100 VLN2
Advanced parameters can only be opened when the control is in stand-by. The first parameter group then appears on the display.
- Put the control into stand-by by holding the power button for about 3 seconds until the display goes blank.
- Confirm the flashing red dot is showing in the bottom right of the blank display.
- Press and hold the right arrow button (4).
- While still holding the right arrow button, press and immediately release the power button (9).
- Release the right arrow button. The first parameter group is now displayed.
Enter boiler service menu and cascade control service levels
Viessmann · Application 8 cascade setup
Access to the boiler service menu and the cascade control's service and coding levels, as printed in the application guide.
- On the boiler, hold the OK and menu buttons for 5 seconds to enter the service menu. (The button symbol is not clear in the text.)
- On the cascade control, press the menu icon, select Service, and enter password viservice.
- For cascade control level 2 coding, select the system configuration icon, select coding 2, and enter password viexpert.
Enter cascade control service level
Viessmann · Cascade control, Vitocrossal CU3A multi-boiler systems
Service level of the cascade control is reached from the menu icon with a service password.
- Press the menu icon on the cascade control.
- Select Service.
- Enter the password viservice.
Enter coding level 1
Viessmann · Vitotronic 200-H control unit
Coding level 1 changes the system codes. Codes not relevant to the installed system are hidden.
- Press OK and the second key simultaneously for about 4 seconds (second key symbol not legible in this extract).
- Select Coding level 1.
- Select the group: General, Boiler, DHW, Heating circuit 1/2/3, or All codes or solar.
- Select the coding address.
- Select the value and confirm with OK.
- To reset all codes to factory settings, select Standard setting in Coding level 1 (this also resets coding level 2).
Enter coding level 1 and change a code
Viessmann · Vitotronic 200-H, Vitodens 200-W B2HB
Opens the coding menu to change boiler, system and heating circuit codes.
- Press OK and the second menu button together for about 4 seconds (button symbol not legible in this copy).
- Select Coding level 1.
- Select the group needed: General, Boiler, DHW, Solar, Heating circuit 1/2/3, or All codes std device.
- Select the coding address.
- Select the value from the tables and confirm with OK.
- To reset all codes to factory settings, select Standard setting in Coding level 1. This also resets coding level 2 codes.
Enter coding level 1 on Vitotronic 200 in cascade
Viessmann · Vitotronic 200 (HO1B) in multi-boiler cascade
The Vitotronic 200 must be put in cascade mode before coding. Use the boiler Service Instructions for the Vitotronic 200 itself. Parts of the key sequence are not legible in this copy.
- Put the boiler in cascade mode first (see the cascade preparation section).
- Press OK and the second menu key together for about 4 seconds.
- Select 'Coding level 1'.
- Select the group: General, Boiler, or All codes std device.
- Select the coding address, choose the value, and confirm with OK.
- Exit the service menu with the back key when finished.
Enter coding level 1 on Vitotronic 300-K
Viessmann · Vitotronic 300-K, MW2B
Coding level 1 on the 300-K is reached from the service menu. Codes are shown as plain text. Codes that do not apply to the installed system are hidden.
- Press OK and the second menu key together for about 4 seconds (the second key is not legible in this copy; check the printed key symbol).
- Select 'Coding level 1'.
- Select the coding group: General, Cascade, DHW, Solar, Heating circuit 1/2/3, or All codes std device.
- Select the coding address, choose the value from the table, and confirm with OK.
- When finished, exit with the back key.
Enter coding level 2
Viessmann · Vitodens 200-W B2HA 80 to 100, 285 to 352
Coding level 2 unlocks all codes, including those in coding level 1. Codes that do not apply to the installed equipment level or to other code settings are hidden.
- Press OK plus the second key (symbol not legible on page 51) together for about 4 seconds.
- Press OK plus the same key again for about 4 seconds.
- Wait for 'Coding level 2' to show on the display.
- Select the coding group: General, Boiler, DHW, Solar, Heating circuit 1/2/3, or All cod. or solar.
- Select the coding address.
- Select the value and confirm with OK.
Enter coding level 2 (numerical codings)
Viessmann · Vitotronic 200 KW2
Coding level 2 gives access to all codings, using numerical addresses.
- Press the two buttons together for about 2 seconds, then confirm to enter coding level 2.
- Select the coding address with the up/down button and confirm.
- Change the value with the up/down button and confirm.
- Wait for 'Accepted', then select further addresses as needed.
- Press the two buttons together for about 1 second to exit coding level 2.
Enter coding level 2 and reset to factory codings
Viessmann · Coding level 2
Coding level 2 holds the full list of boiler and burner codings. Only addresses that match the system and equipment are shown.
- Press the two buttons together for about two seconds, then confirm. Two arrows appear in the display.
- Select the coding address with the up or down button, then press confirm.
- Change the value with the up or down button, then press confirm.
- Press the two buttons together for about one second to exit.
- To reset all codings, press the two buttons together for about two seconds, then press confirm. The display then shows the boiler water temperature.
Enter expert level on Lago FB
Viessmann · Lago FB remote control
Expert level gives access to codes 1 to 17.
- Rotate the mode dial to MODE.
- Use the value dial to select PL (expert level).
- Use the mode dial to select the parameter, then the value dial to set it.
Enter level 2 coding on cascade control
Viessmann · Cascade control, Vitocrossal CU3A multi-boiler systems
Level 2 coding is reached from the system configuration icon with a coding password.
- Select the system configuration icon.
- Select coding 2.
- Enter the password viexpert.
Enter the coding level
Viessmann · Versatronik 300 user interface
Coding level is used for configuration changes. It is entered by holding the ENTER button.
- Press and hold ENTER for 5 seconds to enter coding level.
- Press ESC to leave coding level.
Enter the service code to open the relay test
Viessmann · Versatronik 200 service level
Service tests need a code number. Enter the four digits one at a time, then confirm with OK to open the relay test.
- Open the General/Service level.
- Set digit 1, press the F button to move to the next digit.
- Repeat for digits 2, 3 and 4.
- Press the F button OK to activate the code; the relay test then opens.
Enter the service menu
Viessmann · Vitocrossal 200 CI2 service menu
Service menu is protected by password. On lag boilers, go via fault display 1, then the service symbol on the next screen. The menu exits on its own after 30 minutes.
- Tap the first button shown in the manual (symbol not readable in extracted text).
- Tap Service.
- Enter password viservice.
- Confirm.
- Select the required menu section.
Entering and leaving coding levels
Viessmann · Vitotronic 200 KW2 control unit
Coding level 1 uses plain text and coding level 2 uses numerical addresses. Button symbols for the combinations are not legible in this extract.
- To enter coding level 1 (plain text), press the two buttons together for about 2 seconds.
- To exit coding level 1, press the two buttons together for about 1 second.
- To enter coding level 2 (numerical), press the buttons shown for coding level 2 for about 2 seconds, then confirm.
- To exit coding level 2, press the buttons together for about 1 second.
- To reset codings to factory defaults, use the reset combination, then choose Yes or No for the factory default prompt and confirm.
Expert level code entry
Viessmann · Versatronik 200 controller, expert level
Fitter values in the expert level are locked by a code number. Enter the code at the Code-No input. Write down any new code, because it is needed for later changes.
- Go to the Expert level and open the Code-No input.
- Set each digit, moving to the next with the F button [==>].
- Confirm the code with the F button [OK].
- To change the code, use Change code (0000 - 9999) and record the new value.
- Leave the level with the F button [Cancel].
Extended menu may be blocked
Viessmann · Vitotronic 300-K (type MW2B)
The heating contractor can block the extended menu. In that case only fault messages can be scanned.
- Press the extended menu key to open the extended menu.
- If it does not open, the contractor has blocked it. Scan fault messages only.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.