Updated · by Aurora Star Tech Inc.

Triple evacuation method on a Viessmann mini-split: Alternate evacuation method when it is followed exactly. Always break the vacuum with dry nitrogen.

Homeowner with a ductless mini-split problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: System evacuation, all DLFSHC sizes

How to fix triple evacuation method: step by step

  1. Pump the system down to 500 microns of mercury and keep the pump running for an additional 15 minutes.
  2. Close the service valves and shut off the vacuum pump.
  3. Connect a nitrogen cylinder and regulator. Open until system pressure is 2 psig.
  4. Close the service valve and let the system stand for 10 minutes so dry nitrogen can absorb moisture.
  5. Repeat the sequence as shown in the manual figure.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Mini-Split codes

Models

DLFSHCH06XAKDLFSHCH09XAKDLFSHCH12XAJDLFSHCH12XAKDLFSHCH18XAKDLFSHCH24XAKDLFSHCH30XAKDLFSHCH36XAK

Source: DLFSHC service manual, p. 9. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.