Viessmann Mini-Split: Indoor unit clearances
Indoor unit clearances on a Viessmann mini-split: Keep the top clearance at 5.9 in (15 cm) minimum for proper return airflow. The top clearance may be reduced to 2 in (50 mm) only if the left and right clearances are met. Reduced top clearance can lower unit performance. Keep 4.75 in (12 cm) minimum at the sides, and keep 6 ft (1.8 m) clearance as marked in the clearance figure.
Applies to: DLFSHC indoor units, sizes 06K-36K
How to fix indoor unit clearances: step by step
- Allow space for airflow and service.
- Check top clearance: 5.9 in (15 cm) minimum.
- If top clearance is reduced to 2 in (50 mm), confirm the left and right clearances are met.
- Check side clearance: 4.75 in (12 cm) minimum.
If the unit shows an error code, look it up: Viessmann Mini-Split codes
Models
DLFSHCH06XAKDLFSHCH09XAKDLFSHCH12XAJDLFSHCH12XAKDLFSHCH18XAKDLFSHCH24XAKDLFSHCH30XAKDLFSHCH36XAK
More other tips for mini-split
Source: DLFSHC installation instructions, p. 7. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.