Updated · by Aurora Star Tech Inc.

Compressor check and IPM continuity check on a Viessmann mini-split: Check the compressor windings and the IPM (power module) with a digital tester. The IPM continuity values in Table 11 are not legible on the scanned page.

Homeowner with a ductless mini-split problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Outdoor unit compressor and IPM board

How to fix compressor check and ipm continuity check: step by step

  1. Turn off the outdoor unit and disconnect the power supply.
  2. Discharge the electrolytic capacitors and make sure the energy-storage unit is discharged.
  3. Disassemble the outdoor PCB or the IPM board.
  4. Measure resistance between P and U, V, W, N, and between U, V, W and N with the digital tester.
  5. Compare readings with Table 11 (values not legible in this scan).
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Mini-Split codes

Source: DLFSFBH Service Manual, p. 37. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.