Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Viessmann Boiler: Vitotronic 200 cascade coding entry

Updated · by Aurora Star Tech Inc.

Vitotronic 200 cascade coding entry on a Viessmann boiler: The Vitotronic 200 is coded from the boiler control. The boiler must already be in cascade mode before coding.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Vitotronic 200 multi boiler coding

How to fix vitotronic 200 cascade coding entry: step by step

  1. Confirm the boiler is in cascade mode (see boiler service instructions).
  2. Press OK and the service button for about 4 seconds.
  3. Scroll to service and select with OK.
  4. Scroll to service functions and select with OK.
  5. Scroll to multi-boiler system and select with OK.
  6. When finished, press the exit button to leave.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Boiler codes

Models

HO1BKW2Vitotronic 200, type H01BVitotronic 200, Type HO1B

Source: Vitotronic 200 and 300-K Installation and Service Instructions, p. 28. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Boiler Repair

647-657-2977