Viessmann Boiler: System layout: diverter valve
System layout: diverter valve on a Viessmann boiler: Dedicated boiler pump with no low loss header. A power-open, spring-return diverter valve sends the flow to the tank on a DHW call, and DHW has priority over space heating.
Applies to: Diverter valve systems without low loss header
How to fix system layout: diverter valve: step by step
- Connect the boiler pump to the Vitodens pump module.
- Connect the boiler pump signal to the Versatronik 10.WB1.
- Connect the diverter valve (power-open, spring-return, 120VAC) to the Versatronik 10.WB1 DHW pump output.
- Connect the DHW demand from an aquastat or set-point control to the Versatronik 10.WB1.
- Connect the room thermostat only when the Versatronik Como OT is not used.
If the unit shows an error code, look it up: Viessmann Boiler codes
Source: Versatronik 10.WB1 installation manual, p. 14. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.