Viessmann Boiler: System layout: boiler with low loss header
System layout: boiler with low loss header on a Viessmann boiler: Boiler pump is connected to the boiler pump module. The Versatronik runs the space heating pump and DHW pump and receives the DHW demand and the boiler pump signal. The optional Versatronik Como OT can be used for outdoor reset.
Applies to: Boiler with low loss header
How to fix system layout: boiler with low loss header: step by step
- Connect the boiler pump to the boiler pump module.
- Connect the space heating pump output to the Versatronik 10.WB1.
- Connect the DHW pump output to the Versatronik 10.WB1.
- Connect the DHW demand from an aquastat or set-point control to the Versatronik 10.WB1.
- Connect the boiler pump output signal to the Versatronik 10.WB1.
- Connect the room thermostat only when the Versatronik Como OT is not used.
If the unit shows an error code, look it up: Viessmann Boiler codes
Source: Versatronik 10.WB1 installation manual, p. 12. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.