Viessmann Boiler: Pump outputs not powered
Pump outputs not powered on a Viessmann boiler: The unit has power, but the space heating or DHW pump outputs stay off.
Applies to: Viessmann Vitodens 100-W, WB1A and WB1B with Versatronik 10.WB1
Common causes of pump outputs not powered
- Blown F2 fuse
- No space heating or DHW call present
- No 120VAC signal from the boiler at the WB1 input
- Loose terminal connection
- Faulty RT/DHW interconnection between Versatronik 10.WB1 and boiler
How to fix pump outputs not powered: step by step
- Check the F2 fuse.
- Confirm a space heating or DHW call is present.
- Confirm 120VAC is present at the WB1 input from the boiler.
- Verify the terminal connections.
- Check the RT/DHW interconnections between the Versatronik 10.WB1 and the boiler.
If the unit shows an error code, look it up: Viessmann Boiler codes
Source: Versatronik 10.WB1 installation and operating manual, p. 25. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.