Viessmann Boiler: Open the boiler control unit for cascade work
Open the boiler control unit for cascade work on a Viessmann boiler: Access the Vitotronic 200 control on each boiler before cascade wiring or module installation. Do this on every boiler connected to the Vitotronic 300-K.
Applies to: Vitotronic 200 on each boiler
How to fix open the boiler control unit for cascade work: step by step
- Remove the external accessories connection box cover.
- Loosen the screws at the bottom of the boiler; do not remove them completely.
- Remove the front enclosure panel by lifting it up and pulling it away from the boiler.
- Slide both sides of the programming unit cover closed.
- Release the hinged hooks on both sides of the control unit.
- Lift the cover, then fold down the control unit.
- Release the locking tabs.
- Remove the cover.
If the unit shows an error code, look it up: Viessmann Boiler codes
Models
Vitotronic 200
HO1BKW2Vitotronic 200, type H01BVitotronic 200, Type HO1B
Vitotronic 300-K
MW1SVitotronic 300-K, type MW2B
Source: Vitotronic 200 and 300-K installation and service instructions, p. 9. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.